TEMPERATURE TRANSMITTERS — NT-IB
TECHNICAL DATA
- Microprocessor based
- Housing: ABS plastic.
- Dimensions: 44 mm(diameter)×25 mm(height), installed in thermocouple head
- Input: MV, pt100Ω, thermocouple available
- Isolation: 1000Vac for 1 minute between sensor input and the 4~20mA loop
- Electromagnetic compatibility: EN 50081-2, EN 50082-2
- Internal protection against polarity inversion
- Cold junction compensation for thermocouples
- Thermocouples: Types J,K,R,S,T,N, E and B, according to IEC 60584-1 (ITS-90), Impedance>>1MΩ
- Pt100: Excitation: 180µA
2 or 3-wire connection (for 2-wire sensors, tie terminals 2 and 3 together) α=0.00385, according to IEC 60751 (ITS-90) - Voltage: 0 a 50m Vdc; Impedance>>1MΩ
- Total accuracy: better than 0.25% of the maximum range for thermocouples and 0.15% for Pt100 and voltage
- Response time: ≤ 500ms
- Output: 2-wire 4-20mA, linear with respect to the measured temperature
- Resolution: Power supply: 12 to 35Vdc, across the transmitter
- Maximum load(RL): RL(max.)=(Vdc-12)/0.02[Ω] where: Vdc=Power supply voltage
- Operating temperature: -40 to 85ºC
- Humidity: 0 ~ 90% RH
APPLICATIONS
- Liquids, powders, granules with E>1.5 relative dielectric constant
- Chemicals with dense gas layers above the surface
- Viscose or corrosive materials
- High pressure, high temperature or vacuum
DIMENSIONS
RANGE TABLE
Sensor Type | Range | Minimum Measurement Span |
Thermocouple K | -150 to 1370ºC | 100ºC |
Thermocouple J | -100 to 760ºC | 100ºC |
Thermocouple R | -50 to 1760ºC | 400ºC |
Thermocouple S | -50 to 1760ºC | 400ºC |
Thermocouple T | -160 to 400ºC | 100ºC |
Thermocouple N | -270 to 1300ºC | 100ºC |
Thermocouple E | -90 to 720ºC | 100ºC |
Thermocouple B | 500 to 1820ºC | 400ºC |
PT100 | -200 to 600ºC | 40ºC |